Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

WHAT HAPPEN WHEN CT SECONDARY OPEN DURING LOAD

Answer Posted / v.selvakumar

if ct opens during heavy load , heavy voltage will appear
across ct secondary ,because of no oppossing emf present
primary.result ct will blast

Is This Answer Correct ?    3 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

which type of motor is used in automatic swing gate

1951


What are diffrent type of road taxes?

1922


I have one ct of ratio 3000-2000/1 Amp its knee point voltage mentioned on name plate is 500-333/30mA-50mA at Vk/2. in secondary box there is three terminal named 1S1, 1S2, 1S3 then on which terminal obtained the knee point voltage ie 1S1-1S2 OR 1S1-1S3 & also specify the knee point voltage for the ratio 3000 from name plate.

2389


what kind of technical test that i need to learn because i have an interview tomorrow.. please someone help me..

1964


We have Diesel generator of 200KW. fuel consumption is always same,even connected light load or full load. Is it right?

2124


In parallel operation time both NGR’s close or not close if both close what will happen

3677


for 750 kw LT load what will be the ht kva

1594


What is effect on in zone and out zone fault if CT chosen for phase side is Vk/2<5mA and Neutral side is Vk/2<15mA on REF protection of Transformer

2308


Briefly describe means used by electricity suppliers to influence the flow of active and reactive power in power networks (one for each type)?

1900


in a simple IDMT relay we use neutral point of ct for earth fault then what is the requirement of neutral ct and cbct?

2105


why US countries maintains 110v and 60HZ

2125


where can i get vijaya electricals limited in hyderabad interview auestions can u give me the website address plz

2079


for 5KW resistive load can anyone please suggest me whether to go for UPS/Inverter or Generator depending upon cost calulations

2032


What is the percentage loss for aluminium wire for HT line more than 11KVa

2050


is it possible to have dc motors on single chip

1775