Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

The reason why the sending end and receiving end voltage
sare almost equal when capacitive load is added.

Answer Posted / mubashar ali

When resistive load connected then will be voltage drop (
Vd=I^2R Losses are Directly per potion to square of
current ), there for sending end voltage higher then
receiving end voltage
If connected capacitive load then bothe voltage my be equal
or receiving end voltage higher due lie capacitance, like
the theory of capacitor

Is This Answer Correct ?    0 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is effect on in zone and out zone fault if CT chosen for phase side is Vk/2<5mA and Neutral side is Vk/2<15mA on REF protection of Transformer

2350


A 50Hz,4-pole,3-phase,star-connected synchronous motor has a synchronous reactance of 12ohmsper phase and negligible armature resistances.the excitation is such as to give an open-circuit voltage of 13.2kilovolt.the motor is connected to 115kilovolt, 50hertz supplying. what maximum load can be the motor torque,line current and power factor?

2417


What are the disadvantages of hydropower?

1205


why should the primary of transformer be connected in delta in a heat run test?

1961


block diagram of 2 ups system connected in parallel mode?

2057


What is Icu and Ics and what is difference b/w them. please tell me how to calculate a size of a copper bar for a system or a breaker... reply on... king.arish@gmail.com would be waiting for a logical answer.

2441


what is errection pcbs?

1905


Why dry type cast resin transformers tap link blast in HV side while power shut down times on load?

2306


in control scheme dc logic wiring commonly using negative loop,what is the reason?if we use positive looping what will happen?

2317


why US countries maintains 110v and 60HZ

2172


WHAT IS SHORT CIRCUIT STRENGTH OF 100 AMPS MCCB?

2099


What effect does a very low impedance have on the Voltage regulation? On the short-circuit current?

6277


What range of speed can you get with the field control method of speed control of d.c. Shunt motor?

1132


i am studying in final year can i allowed for 23rd UES of Indian army

2103


any idea abt REVERSE METERING concept.........?

2219