Answer Posted / gajju.
so long as physical state of conductor remains same the
current flowing through it is directly proportional to
voltage applied.and vice-versa.
I=V/R or V = IR
| Is This Answer Correct ? | 5 Yes | 1 No |
Post New Answer View All Answers
why the rotor current becomes in steady state during high slip region? please verify with equations.
What are the main advantages of bode plot?
why you don not show protection and type of isolation in key single line diagram?
Explain the working principle of Synchronous Generator and Assynchronous generator?
1. If 8.35%Z means the percentage impedance of 132kV-line from power company, we will like to reconfirm its base capacity.
why ten delta testing is carried out on power transformer
generally in LT and MV motors we are using 3.5Coresx16,25,35,50 etc cable for supply.although motors is earthed at two point and having all protection.then why we are using that 1/2 core for earthing the motors.while in HT cable we are using only 3core cable for motor supply.generally lt and mv motors are delta connected and ht motors having star connection.whethere it is having any relation with winding connection( star or delta).all motors i am talking about are dol only.can anybody solve my confusion.thanks...
what is EIB lighting control system? what is the advantages of this system?
what is the effect of vector group while phase sequence of a generator changes,whether the vector group changes or not
An ELHNC 80amp 240v 30mA RCD is tripping periodically, every 30 - 180 seconds is it safe to disconnect the protection circuit?
A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.
How to decide CT & PT ratings for a given transmission line carrying some rated voltage?
WHAT IS THE DIFFERENE IN ACTION OF MCB,MCCB,RCCB
what is the synchronous timer ? and it applications.
How to determine stage of Automatic Power factor controlling Relay(Apfcr)?