why skin effect is decreases with decrease with frequency?
why skin effect occur
Answer Posted / pyobik
skin effect is a phenomenon occuring in solid conductor
carrying AC supply, which leds the current to flow maximum
at the surface, this current density difference at the core
and the surface is due to the flux linkage in the core of
the conductor is more and leads to greater inductance
inside the core. And the skin effect occurs!
and the inductance is dependent on the frequency.
| Is This Answer Correct ? | 38 Yes | 4 No |
Post New Answer View All Answers
CALCULATE THE TOTAL VOLTAGE DROP AND SELECT THE CABLE SIZE IN MM-SQARE FOR A PANEL-262KW AT 110 METER FROM THE SOURCE SUPPLY , SUPPLY VOLTAGE 240/415
What is quadrantal symmetry?
Sir, I have applied for the of Jr.engineer(Electrical & Electronics) & ASST. LOCO PILOT at ALL RRB BOARDS. please send me all RRB Boards solved papers in the year of 2001 tO till date. i requested send me the papers to my id as soon as possible (jet_0991@yahoo.com). (This is very urgent) Thank You,
Who many reason of ignition fail ?
Generator,motor and alternator Working principal Please explain easily
If we have to find the inductance of a dc shunt motor then by giving dc supply or ac supply and what is the reason for it. (this example is from "to determine the transfer function of a dc shunt motor ")
The loads are connected with phase and ground then why current flow as the loads ?
what are the pecularity of shaver sockets ?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
Why did lightening arrestor solid copper rod head is sharp on mobile tower top?
How many types of protection relays are there based on the characteristic?
WHAT IS THE FAULT WHEN 100HP TURBINE MOTOR TRIPS, LIST THE FAULTS AND ITS TRABULESHOOTING TIPS.. MY AUTO TARNSFORMER STARTER TRIPS
What is meant by turbo alternators?
What is cable tray, its type, and its support?
Generation of voltage for each phase are same of a turbogenerator.Although the short circuit current flow when two phase of turbogenerator are shorted(where current can't flow without potential difference),why?