Un-Answered Questions { IBM MainFrame }

How many minimum number of line codes does PL/1 DB2 program requires?

2590


If an array is multi-dimensional dynamic array how do you deal with it & provide me some examples?

1991


What are the error (ONCODES) codes did you encounter in PL/1 programme?

2478


I want to set position for a particular text in a certain position in several of my cics maps.Please provide me with a solution. Ex: If "F1-Help" has to be set to pos(4,27) always in all the maps within a PDS.

1946


what u mean by csrloc and rtncsrloc in rpgIV in as/400.Give an eg? to do...give some coding...what is row no and column no ???..if possible...give a no of lines coding....please

3952


Mainframes gets a text file that contains the name of the file. Now using JCL i want to locate that file name in the mainframe system and perform further processing. Please tell how to proceed

1974


Is therE anybody who knows about TICKLER FILE of RM.??thank you

1547


Suppose there are 2 Input files Infile-1 and Infile-2. Both the Files contain Employee Records. You need to compare both the files and Write the Common Records in third file named Outfile. How can we do this using File-Aid?

2223


IDENTIFICATION DIVISION. PROGRAM-ID. UPDT. AUTHOR.anbu. DATE-WRITTEN. AUG 13. ENVIRONMENT DIVISION. INPUT-OUTPUT SECTION. FILE-CONTROL. SELECT CMSTR ASSIGN TO CINP1 ORGANIZATION IS INDEXED ACCESS IS SEQUENTIAL RECORD KEY CM2-KEY FILE STATUS IS WS-CMSTR-FST. SELECT CTAB ASSIGN TO CINP2 ORGANIZATION IS ACCESS IS SEQUENTIAL RECORD KEY VSAM-WHSE- KEY FILE STATUS IS WS-CTAB- FST. DATA DIVISION. FILE SECTION. FD CMSTR. COPY RXCYFC20. FD CTAB. COPY AITYWHSE. ************************************************************ ****** *** WORKING STORAGE VARIABLES *** ************************************************************ ****** WORKING-STORAGE SECTION. 01 WS- VARIABLES. 05 WS-EB PIC X(02) VALUE ZEROES. 05 WS-DIV PIC 9(03) VALUE ZEROES. 05 WS-CMF-RECS-REWRITTEN PIC 9(01) VALUE ZERO. *** FILE STATUS VARIABLES *** 05 WS- FILESTATUS. 10 WS-CMSTR-FST PIC 9(02) VALUE ZEROES. 10 WS-CTAB-FST PIC 9(02) VALUE ZEROES. *** END OF FILE VARIABLES *** 05 WS-CMSTR-EOF PIC X(01) VALUE 'N'. 88 WS-CMSTR-EOF-YES VALUE 'Y'. 88 WS-CMSTR-EOF-NO VALUE 'N'. 05 WS-CTAB-EOF PIC X(01) VALUE 'N'. 88 WS-CTAB-EOF-YES VALUE 'Y'. 88 WS-CTAB-EOF-NO VALUE 'N'. **** ERROR VARIABLES **** 05 WC-ABEND-900 PIC 9(03) VALUE 900. 05 WE-ERR-CODE PIC 9(02) VALUE ZEROES. 05 WE-ABEND-CODE PIC 9(03) VALUE ZEROES. ************************************************************ **** ********* PROCEDURE DIVISON ********** ************************************************************ **** PROCEDURE DIVISION. 0000- BEGIN. PERFORM 1000-INITIALISE THRU 1000- EXIT. PERFORM 2000-PROCESS THRU 2000- EXIT UNTIL WS-CMSTR-EOF- YES. DISPLAY 'WS-CMF-RECS-REWRITTEN :' WS-CMF-RECS- REWRITTEN. PERFORM 5000-CLOSE THRU 5000- EXIT. GOBACK. 0000- EXIT. EXIT. 1000- INITIALISE. OPEN I-O CMSTR. EVALUATE WS-CMSTR- FST WHEN 00 WHEN 97 CONTINUE WHEN OTHER DISPLAY 'ERROR IN READING INPUT FILE: ' DISPLAY WS-CMSTR-FST MOVE WS-CMSTR-FST TO WE-ERR-CODE PERFORM 9999-ABEND-PARA THRU 9999-EXIT END-EVALUATE. OPEN INPUT CTAB. EVALUATE WS-CTAB-FST WHEN 00 WHEN 97 CONTINUE WHEN OTHER DISPLAY 'ERROR IN READING INPUT FILE: ' DISPLAY WS-CTAB-FST MOVE WS-CTAB-FST TO WE-ERR-CODE PERFORM 9999-ABEND-PARA THRU 9999-EXIT END-EVALUATE. 1000-EXIT. EXIT. 2000-PROCESS. READ CMSTR. EVALUATE WS-CMSTR-FST WHEN 00 CONTINUE WHEN 10 SET WS-CMSTR-EOF-YES TO TRUE GO TO 2000-EXIT WHEN OTHER DISPLAY 'ERROR IN READING INPUT FILE: ' DISPLAY WS-CMSTR-FST MOVE WS-CMSTR-FST TO WE-ERR-CODE PERFORM 9999-ABEND-PARA THRU 9999-EXIT END-EVALUATE IF CM2-RECORD-TYPE-SOLD-TO MOVE CM2-ENTERING-BRANCH TO WS-EB PERFORM 3000-READ THRU 3000-EXIT UNTIL WS-CTAB-EOF-YES END-IF. 2000-EXIT. EXIT. 3000-READ. MOVE WS-EB TO VSAM-WHSE-CD. MOVE 'WHSE' TO VSAM-WHSE-ID. READ CTAB. EVALUATE WS-CTAB-FST WHEN 00 MOVE WHSE-DIV-CODE TO WS-DIV PERFORM 4000-REWRITE-CMF THRU 4000-EXIT WHEN 10 SET WS-CTAB-EOF-YES TO TRUE GO TO 3000-EXIT WHEN OTHER DISPLAY 'ERROR IN READING TABLE FILE: ' DISPLAY WS-CTAB-FST MOVE WS-CTAB-FST TO WE-ERR-CODE PERFORM 9999-ABEND-PARA THRU 9999-EXIT END- EVALUATE. 3000- EXIT. EXIT. 4000-REWRITE- CMF. IF WS-DIV = 250 OR 252 MOVE 'F' TO CM2-FREIGHT- TYPE MOVE 1 TO CM2-FREIGHT-THRESHOLD- AMT ADD +1 TO WS-CMF-RECS- REWRITTEN REWRITE CM2-SOLD-TO- RECORD DISPLAY 'RECORD UPDATED' END- IF. * EVALUATE WS-CMSTR- FST * WHEN 00 * CONTINUE * WHEN OTHER * DISPLAY 'FILE NOT UPDATED' * DISPLAY WS-CMSTR- FST * MOVE WS-CMSTR-FST TO WE-ERR-CODE * PERFORM 9999-ABEND-PARA THRU 9999-EXIT * GO TO 4000-EXIT * END-EVALUATE. 4000-EXIT. EXIT. 5000-CLOSE. CLOSE CMSTR CTAB. 5000-EXIT. EXIT. 9999-ABEND-PARA. COMPUTE WE-ABEND-CODE = WC-ABEND-900 + WE-ERR-CODE CALL 'ILBOABN0' USING WE-ABEND-CODE GO TO 5000-CLOSE. 9999-EXIT. EXIT. 5000-CLOSE. CLOSE CMSTR CTAB. 5000-EXIT. EXIT. 9999-ABEND-PARA. COMPUTE WE-ABEND-CODE = WC-ABEND-900 + WE-ERR-CODE CALL 'ILBOABN0' USING WE-ABEND-CODE GO TO 5000-CLOSE. 9999-EXIT. EXIT. //this program is giving maxcc=0, but not updating..

3342


I have one ps file in which there are 3 fileds emp_no,emp_name and leave_app.this ps file information give the detail of employee which is going to apply for leave.suppose emp_no=113430,emp_name=ajay,leave_app=1 that means he is going to apply for 1 day leave.and accordingling the table in db2 will be updated means if he has that no of leave in his account then he will get dat leave and updated acc. in table(leave_balance=previous leave present in table-leave_app).Now i want to check whther the updated result is correct or not by comparing the two ps file using IEBCOMPARE or icetool so what is going to be the two ps file and how its is going to be compare.

2013


If anyone has latest IBM Certification Dumps can you pls forwards it to me

2506


SET is the ANSI standard for variable assignment, SELECT is not. SET can only assign one variable at a time, SELECT can make multiple assignments at once. If assigning from a query, SET can only assign a scalar value. If the query returns multiple values/rows then SET will raise an error. SELECT will assign one of the values to the variable and hide the fact that multiple values were returned (so you'd likely never know why something was going wrong elsewhere - have fun troubleshooting that one) When assigning from a query if there is no value returned then SET will assign NULL, where SELECT will not make the assignment at all (so the variable will not be changed from it's previous value) As far as speed differences - there are no direct differences between SET and SELECT. However SELECT's ability to make multiple assignments in one shot does give it a slight speed advantage over SET.

2155


How is it possible to do a cross-sysplex copy of a PDS dataset by running one JCL on the target sysplex? I tried to use IEBCOPY with SUBSYS & CSM as follows: //CSMTRAN1 EXEC PGM=IEBCOPY //SYSPRINT DD SYSOUT=* //SYSUT1 DD DSN=PDS-Dataset-name-from,DISP=SHR, // SUBSYS=(CSM,'SYSPLEXNAME-FROM') //SYSUT2 DD DSN=PDS-Dataset-name-to,DISP=OLD, // SUBSYS=(CSM,SYSPLEXNAME-TO') //SYSIN DD DUMMY This did not work. I always get the following error "IEB1071E DD NAME SYSUT1 IS SUPPOSED TO BE A PARTITIONED DATA SET BUT IT HAS NO DIRECTORY. EXPECT A TERMINAL I/O ERROR. (DS1LSTAR=X'000000' DS1DSORG=X'0000' JFCDSORG=X'0200') " The source dataset is a catalogued pds dataset with many entries. The target dataset is allocated in the same job some lines before the transfer. I got an example like this for PS datasets with IEBGENER. But for PO datasets there should be a similar possibility...

3657


Immediate Job opening for mainframe professionals in Keane Bangalore. Please find the below details: Organization: Keane India Location: Bangalore Skill: COBOL, JCL,VSAM,DB2,CICS,IMS,REXX,CLIST Exp: 1 to 4 years only Employment Type: Permenant Employee Note: If you have attended keane interview in past 6 months please ignore this job opening. Please respond to email id keanemfjob@gmail.com OR keanemfjob@yahoo.in with your latest resume and following details, We will contact you within 24 hours: Total IT Exp: Exp in Mainframe: Current CTC: Expected CTC: Notice Period:

3532


how do u conduct impact analysis?

1806