RMAN-08036: channel string: could not create controlfile
record for string string
Answer / guest
Cause: The record identifying the named file was no longer
present in the target database controlfile, and repeated
attempts to inspect the file were unsuccessful in creating
the record. This could be because the circular-reuse section
of the controlfile which holds information about the
specified type of file is too small and there is other
database activity which is causing the record to be
overwritten before it can be used.
Action: Try increasing either the size of the controlfile
circular-reuse section for this file type (datafile copy or
archived log, as indicated in the error message, or the
control_file_record_keep_time initialization parameter. If
neither of those remedies works then contact Oracle.