RMAN-06170: no controlfile copy found with offline range
recid string stamp string datafile string
Answer / guest
Cause: This offline range is needed for recovering the
specified datafile, but the offline range record has aged
out of the current controlfile and no controlfile copy with
the record could be accessed. At least 1 controlfile copy
containing the offline range was found in the recovery
catalog and was in AVAILABLE status.
Action: Query the rc_controlfile_copy view for the names of
all controlfile copies, then issue a CHANGE CONTROLFILECOPY
... VALIDATE; command for them. Then reissue the RECOVER
command.
Please add more information about this Error
| Is This Answer Correct ? | 0 Yes | 0 No |
ORA-16219: This database is not preparing to switch over.
ORA-23331: column group string does not exist
LFI-00116: Unable to close file in operation string.
ORA-29808: specified primary operator binding does not exist
ORA-38423: Attribute set created from an ADT may not be extended.
ORA-38465: failed to create the privilege checking trigger due to: string
ORA-30484: missing window specification for this function
QSM-02061: one or more joins present in mv
ORA-27204: skgfpqr: sbtpcqueryrestore returned error
TNS-04084: WARNING: Non-reloadable parameters have retained their values.
NZE-29112: Cannot access attributes from a PKCS #12 certificate bag.
NZE-28855: Unsupported SSL operation