PLS-00925: native compilation failed: Unable to create C
file (string string)
Answer / guest
Cause: Native compilation of a PL/SQL program failed because
the C file could not be created. It is likely that the
system paramter plsql_native_library_dir does not reference
a writable, existing directory
Action: Ensure that the system parameter
plsql_native_library_dir references a dirextory which
exists, and is writable.