PCC-00113: Value of DBMS option invalid with given value of
MODE option
Answer / guest
Cause: When MODE={ANSI14 | ANSI13}, DBMS=V7 was specified,
or when MODE=ANSI, DBMS=v6 was specified. These option
settings are incompatible. Note that the DBMS option was not
available before release 1.5 of the Oracle Precompilers.
Action: With DBMS=V7, instead of MODE={ANSI14 | ANSI13},
specify MODE={ANSI | ORACLE}. With DBMS=V6, instead of
MODE=ANSI, specify MODE={ANSI14 | ANSI13 | ORACLE}, but
MODE=ORACLE is recommended.