PCC-02101: Unable to open input file
Answer / guest
Cause: The precompiler could not open the input file. This
is the .pc file specified in the INAME=option. This means
that the file does not exist, that a directory was
incorrectly specified in the pathname, or that the person
running the precompiler does not have read permission for
the file. This message could also result from
operating-system errors. For example, an unmounted file
system or disk I/O errors, could trigger this error.
Action: Check that permission to read the file exists and
that the full pathname has been specified correctly. Check
for operating- system problems. See also the operating
system-specific Oracle documentation.
Please add more information about this Error
| Is This Answer Correct ? | 0 Yes | 0 No |
PLS-00552: flexible character set is not allowed on component element
NNL-00876: Total update processing time: string
PLS-01401: Identifier over 18 characters long
ORA-06548: no more rows needed
ORA-19603: cannot backup or copy active file with KEEP .. UNRECOVERABLE option
RMAN-06058: a current controlfile cannot be included along with a standby controlfile
ORA-07552: sftget: $GET failure
ORA-14043: only one partition may be added
ORA-12426: invalid audit option
RMAN-08109: channel string: restored block(s) from backup piece string
ORA-30477: The input select_clause is incorrectly specified
DRG-11853: No Host Name Found