PCB-00637: Host variable is not an exact binary integer



PCB-00637: Host variable is not an exact binary integer..

Answer / guest

Cause: A host variable was given that was not declared to be
of some acceptable exact binary integer type. Generally,
when this error occurs, a signed or unsigned integer type
was expected. Floating point or otherwise imprecise numeric
types are considered erroneous.

Action: Replace the problematic host variable with one that
was declared using a proper binary integer type.

Please add more information about this Error

Is This Answer Correct ?    0 Yes 0 No