PCB-00637: Host variable is not an exact binary integer
Answer / guest
Cause: A host variable was given that was not declared to be
of some acceptable exact binary integer type. Generally,
when this error occurs, a signed or unsigned integer type
was expected. Floating point or otherwise imprecise numeric
types are considered erroneous.
Action: Replace the problematic host variable with one that
was declared using a proper binary integer type.