ORA-38739: Flashback log file is more recent than control file.
Answer / guest
Cause: The control file change sequence number in the
flashback database log file was greater than the number in
the control file. This implies that the wrong control file
was being used. Note that repeatedly causing this error can
make it stop happening without correcting the real problem.
Every attempt to open the database will advance the control
file change sequence number until it is great enough.
Action: FLASHBACK DATABASE can only be used with the current
control file. If it is not available, then a restore and an
incomplete recovery must be performed instead.
Please add more information about this Error
| Is This Answer Correct ? | 0 Yes | 0 No |
ORA-24905: invalid recepient protocol attribute passed into OCI call
PCC-00109: Dynamic SQL and PL/SQL are Oracle extensions to ANSI SQL
TNS-12674: Shared server: proxy context not saved
DRG-13307: 'off'=string and 'len'=string references character past end-of-file of string character document, at line string
RMAN-20034: resync not needed
ORA-02459: Hashkey value must be a positive integer
ORA-30379: query txt not specified
ORA-19605: input filename must be specified
ORA-31698: Error stack buffer size must be specified and must be greater than 0.
ORA-29883: cannot create a domain index on column expressions
ORA-08330: Printing not supported
ORA-10584: Can not invoke parallel recovery for test recovery