ORA-01609: log string is the current log for thread string -
cannot drop members
Answer / guest
Cause: A member of the current log for a thread cannot be
dropped.
Action: If the thread is opened, request a log switch by the
instance that is using it. If it is not open, disable the
thread, manually archive the log, or clear it.