ORA-16138: end of log stream not received from primary
Answer / guest
Cause: The standby system has not received notification that
the primary system log stream has been terminated. A
graceful switchover is not possible.
Action: Verify that the primary log stream has been
terminated. Ensure that the standby has applied all
necessary redo from the primary system and, if appropriate,
reissue the graceful switchover command.