Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

units of pressure,flow, level,temperature?
principle of pressure gauge?
calibration of pressure tx., level tx., temperature tx.flow
tx.?
description of two wire ,three wire and four wire R.T.D.?
WHAT IS INPUT AND OUTPUT OF TX.?
WHAT IS INPUT AND OUTPUT OF R.T.D. AND THERMOCOUPLE?
WHAT IS HOT LOOP AND COLD LOOP?
WHAT IS INPUT AND OUT PUT AND OUTPUT OF D.C.S. AND P.L.C.?
PRINCIPLE AND WORKING OF HART?
WHAT IS PNP AND NPN PROXY?
CALIBRATION OF PRESSURE ,LEVEL ,FLOW SWITCH?
DESCRIPTION OF FIELDBUS FOUNDATION?
WORKING OF SOV.?

Answer Posted / sathish

1.unit of pressure
kg/cm2,psi,bar,atm,inchs of h2o,mmof h2o
2. unit of flow
gpm,1/min,hour,cubic feet per hour,per min,metre cubs per
min& hour.
3.unit of level
mostly related with pressure.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the difference between modbus,fieldbus & profibus

2474


how to calibrate steam control valve in steam turbine

3395


Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75 The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is: WARNING: Could not connect to equalize destination. (7001) Retrying. Number of retries = 0/1 ERROR: LdXopsLoadMain: connect error 10060 ERROR: Processing terminated due to connection error. (7002) Equalization end with errors. STN0149 ---- ERROR = 2 WARNING = 1 ---- Background: >Updated the ExaOPC software on the STN from 3.60 to 3.75 >STN operating system is Windows Server 2008 R2 >HIS operating system is Windows Server 2016 Stanard Solutions attempted include: >Ensuring all IP addresses are correct and all networked devices can be pinged. >The ability to ping a device using its host name from another device ( from HIS) >Ensure both devices firewalls are disabled. >The antivirus installed on the STN is disabled. >Ensuring both devices are within the same workgroup. >Added both devices to each other's Host and LMHost files. >Running IT Security tool after changing any administrative settings.

2257


what is exact time to study dcs and plc cources

2107


What is the diffrence between digital signal processing and discrete signal processing?

2044


how to change measuring units from mmwc to cubm/h in rosemount air flow transmitter with hart communicator fluke 744

2454


How is flow measured in square root?

1348


hi sir yhis is zahid ali i am preparing for the jspl at oct.4.please send me the recently updated sample paper.

2230


how can leve transmetter calibate in feild .and also put cv and flow plz .....

2296


Explain bernoulli’s theorem. State its application.

1231


Good evening all I need a small favour regarding reliance paper i wanna probable sample papers(e&i) of reliance. if any of u have any idea about dis then plz mail me back.i belongs to electronics and instrumentation engg.so i need e&i papers. thanking u....

2140


WHAT IS MEANT BY PROJECT MANAGEMENT STRATEGIES IN INSTRUMENTATION?

3630


in natural gas indirect water bath heater,how to prevent the problem of backfire from firetube during ignition...becoz of this backfire performance of wbh is going low.

2860


What is the PLC configuration in Cement industry?

3861


why we should maintain neutral earth voltage below 1V while calibration? why cant it be 1.2V or 2V

2498