Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

wat s the difference between diode and capacitor

Answer Posted / tinku

diode is an electronic switch but capacitor is a filter.

Is This Answer Correct ?    5 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Motor,transformers,capacitor tubelight etc....

1581


What is a surge supressor why its is used in synchronous generators

1962


Why only sinusoidal ac voltages are generated?why not triangular or sawtooth?

2036


WHAT IS START TO INDUCTION MOTER IN STAR TO DELTA OF >5HP ?

1818


how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING) I O (current operating)?

2155


What are the special cables required for explosion proof wiring?

3507


What are the Return ( Monthly / quarterly/ Annual submitted to Electical Inspector for an establishment (Factory in Maharashtra-- Small scale category having seperate HT line of 22KV ) as per Maharashtra Electricity Act

1978


Does the direction of rotation of d.c. Shunt motor would get reversed if the armature current and field current both are reversed?

1095


What is line resistance of cable & how it can be measured ?

1438


what is (+) and (-) in generator field detector stand for?

1782


HELLO EVERYONE, I RECENTLY HAVE FOUND ONE PROBLEM, I WAS TAKING NO LOAD TRIAL OF AN HT MOTOR 920 MOTOR , 1440 RPM , 6.6 KV, WITH AUTO TRANSFORMER. AT 450 V, LOAD WAS 40 AMP AND SPEED WAS 250 RPM. BUT AS WE INCREASE VOLTAGE FROM 450 TO 480V, LOAD BECOME 41 AND SPEED REDUCED TO SOME RPM . SO WHICH PHENOMENON ACTED HERE FOR REDUCING SPEED.?? AND IS IT HAPPENING ALWAYS OR IT IS RARE? I ALSO HAVE FACED SUCH PROBLEM WITH FEW LT MOTOR ALSO.

1907


what is the isolation transformer. what is the isolator?

2025


I have c license but I don't know eligibility of Max Kilo Volts under the electrical licensing board.

1645


how to electrically make connection to ferroli GN2N?

1879


what is the maximum permissible limit value of leakage current and leakage counter reading to replace lightining arrester?

5079