Categories >> Engineering >> Electrical Engineering
 


 

 
Question how to check the earth resistance value& what is the
minimum earth resistance for good earthing sysytem.
 Question Asked In Companies :: BSNL, DMRC, Epoch, KPTCL, Siemens, Wipro, SIEA, Brookfield, Power Control,     < I also faced this Question! >
 Question Submitted By :: suresh
  Answer Posted By  
 
Answer
As such there is no any standard of earth resistance value,
Its varies on different type of soil resistivity. Idley it
should be 0, but in different kinds of soil for electrical
equipment it should be better to below 10 Ohms and for
electronic equipment it should be better to below 5 ohms.

Is This Answer Correct ?    77 Yes 24 No


 
  praveen kumar jain
 
View All Answers
 
 
Please Help Members By Posting Answers For Below Questions
 
 Question Views   Select
 
what is the purpose of slope in the differential relay?why we are using two slope?but in busbar differential we are using only one slope.why? 890
explain supply side and demand side energy management with advantages & disadvantages 380
how to test the electrical panel.ht lt mcc pcc. 402
Refernce currents are to be generated using refernce cueernts how can this be done?? 336
How to calculate mf when meter equipment and meter are connected 17
Sir pl provide 5 year sample paper for post junior engineer(electrical).I have currently applied for junior engineer (electrical) on RRB Ajmer 1961
1600kva capacity Transformers how the bucholz relay,Oil temperature,winding,surge relay relays setting are to be done 330
what is errection pcbs? 332
how to copy from plc ge fanuc versamax series,all input and output, adress, and printout. 522
i have install 750 kva distribution transformer at my site and want to do neutral earthing. what calculations should i follow to determine earthing conductor material and size? 378
What will happened if the neutral of the (star connected secondry) Xformer disconnected? (if its Above KVA rated one) 422
what is mean by ideal infinite bus? why it is required to consider in fault short circuit calculations? 811
what is the advantage of connecting capacitors in delta than in star? 427
What is the effect on in Zone and out zone fault if Phase side CT is Vk/2<30 mA and Neutral side is CT is Vk/4<30 mA for Transformer REF protection 491
What is meant by Load Encroachment in OHL Feeder Protection? 1362