Question Why a starter is used for a motor?
 Question Asked In Companies :: L&T, Nilachal Polytechnic,     < I also faced this Question! >
 Question Submitted By :: ravi
  Answer Posted By  
 
Answer
generally the resistance of armature is very small i.e in
term of .05ohm or like this.this is due to reduce the
losses.if the motor is connected direct supply high current
will flow and it may burn the armature winding.thats why
starter is connected between supply and motor which reduces
the starting current and provided smooth operation

Is This Answer Correct ?    120 Yes 17 No


 
  sabyasachi kanungo
 
View All Answers
 
 
Please Help Members By Posting Answers For Below Questions
 
 Question Views   Select
 
WHAT IS THE WORKING PRINCIPLE OF A GENERATER.how is a GTG (Gas TURBANE Generater) working.plz explane 644
HOW TO REDUCE POWER PLANT AUXILIARY POWER CONSUMPTION? 1396
1.Can we use 6.6/11KV 300sq mm xlpe 3core cable for LT use (415 Volt). 2. If we use it for LT then what is the current rating 106
when we have to use UPF wattmeter and LPF wattmeter? what is the difference between UPF and LPF wattmeter in terms of construction? 635
When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this< 497
what is the voltage regulation for unity and zero power factor? 267
PLZ EXPLAIN THE INTERLOCKING AND CONTROLLING OF CONTACTORS????HOW CAN I DO THAT? 2438
what is meant by CT`s saturation ? Can we use Metering CT`s with Protetection CT`s ? 333
As you achieve greater success with the company after some years, Will you like to be a share holder in our company? 1063
I am EEE student i want to improve my core side skills.how cn i approach it? 823
Plugging is a phenomenon to= A braking the motor B to accelerate the motor C to run IM as generator D to start the motor 890
What is the end effect of linear induction motor ?? 314
what reason of line current and phase current in star connection and line current and phase current not equal in delta connection? 484
I need the list of Universities who have summer intake for BS degree in Electrical Engineering.? 521
please tell me how a surge protector work on a DC 48Volt.? please describe briefly. 346