Question What is the function of Lightning Arrester & Wavetrap in
Power system ??
 Question Asked In Companies :: Bhel, Infosys, NTPC, Energy Infratech,     < I also faced this Question! >
 Question Submitted By :: crmeena
  Answer Posted By  
 
Answer
LIGHNING ARRESTER IS THE NON LINEAR RESITANC (ZINK OXIDE)
WHICH GVES LOW RESISTENCE PATH TO HIGH VOLTAGE AND HIGH
RESISTENCE TO LOW VOLTAGE,IT IS CONNECTED IN SHUNT WITH
EUIPMENT.

Is This Answer Correct ?    35 Yes 7 No


 
  smita
 
View All Answers
 
 
Please Help Members By Posting Answers For Below Questions
 
 Question Views   Select
 
sir i have a car stereo system and there is jack on him so can u tell me a way to find out their power terminals on the jack or on the circuit board" 301
63MVA,220KV/6.9KV Transformer LV side neutral is connected to Earth pit through NGR. Whether this earth pit required to connect with near by below grouding earth mat or it is to be kept separate? 597
i need list of swg(standard wire guage) or area of conductor v/s current carrying capacity of conductor copper & alluminium... 212
What will be the voltage impact on secondary side of two transformers with different vector groups when both voltages are compared. 360
How much dc volt applied in cathodic protection system? 574
How is The split core current transformer working ? 754
plz explain the auot-reclosing circuit in electrical engineeing 483
I have two AC generators, the first rated 2680KVA for 380V/4345A/pf:0.7 and the second rated 3461KVA for 5500V/363A/pf:0.8. I want to parallel the two generator to a bus. The second generator passes through a transformer to down the voltage to 380V and a part of its power goes to another bus so that it's only a part of the total power of the second generator taht goes to the considered bus. I have two Basler DECS100 AVR regulator. How can I make the synchronization ? What others equipments must have ? 329
What types of CMOS memories have you designed? What were their size? Speed? Configuration Process technology? 1054
why in america the supply frequency is applied as 60 HZ. but in india we use 50 HZ. 413
how to calculate the formula of cable size if motor kw is given 419
This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details. 850
Grid fault level [KA]? 502
1. If 8.35%Z means the percentage impedance of 132kV-line from power company, we will like to confirm its base capacity? 301
We have studied about many techniques for finding the stability of system, ROOT LOCUS, ROUTH, BODE PLOT, POLER PLOT etc. In these which is used where. what are the difference among them... PLZ tell me....... 439
E-Mail New Answers        Answer Selected Questions