Question
In stepdown transformer 11/415 volt two nos.(R & Y)HT side  
fuse is blown ,what will be voltage of ry,rb,yb in 
secondary side
Rank Answer Posted By  
 Question Submitted By :: Jitu
This Interview Question Asked @   NTPC
I also faced this Question!!   © ALL Interview .com
Answer
depends upon the configuration of the
transformer...whether it is star delta,star star.....
 
0
Harish
 
 
Answer
If blowing of HT side fuses result in zero magnetising
current in the primary winding, then there will not be any
voltage in ry,rb,yb on the secondary side
 
0
Elangovan T
 
 
Question
How to convert resistance value at 20 degree to 90 degree?
Rank Answer Posted By  
 Question Submitted By :: Kumar
I also faced this Question!!   © ALL Interview .com
Answer
Ro -resistance at o degre centigrade 
Rt -resistance at t degre centigrade 
we have formula 
Rt = Ro(1+alpha t)
here alpha is cofficient of resistivity
 
0
Sanjeet Swarnakar
 
 
 
Question
how to write the program for single push button by using 
ladder diagram
Rank Answer Posted By  
 Question Submitted By :: Guest
This Interview Question Asked @   DigiTech
I also faced this Question!!   © ALL Interview .com
Answer
if i0.0
then o0.0
othw reset
 
3
Anurag Ispat Ind. Ltd.
 
 
Answer
1. Create a Push button
2. connect a Counter series to PB
3. create a compare button 
4. initilize 1 at one end
5. Counter output in another
6. Connect the Coil which has to be energised
7. initilize 2 at one end
8. Counter output in another
9. Connect the Coil which has to be deenergised 
 
0
Akg D Gr8
 
 
Answer
SIMPLE LOGIC FOR MOTOR ON AND OFF 

   P.B(NO)                    Motor
[----[ ]----------i--------------()---
[    I0.0         i             Q0.0
[                 i
[   P.B(NC)       i
[----[\]-----( )--i
[    I0.1    Q0.0*
[

NO - Normally Open
NC - Normally Close

I0.0 - Input Address in PLC for P.B(NO) to Start the motor.
I0.1 - Stop Push Button(NC)Address.
Q0.0 - Out put adress(Motor)
* - Means the output Q0.0 is used for hold the motor ON.

Further Details - isonafar@gmail.com
 
0
Ibrahim S
 
 
Answer
[----[ ]----------i--------------()---]
[    PB           i              OP   ]
[                 i                   ]
[                 i                   ]
[----[ ]----------i                   ]
[    OP*                              ]

OP* Output Energies memory contact!
 
0
A
 
 
Answer
Acually the question is for using only one PB for ON and 
OFF the motor, not one PB for ON and one PB for OFF.

[     PB         M2         O/P    ]
[-----[ ]--------[/]--------( )----]
[           i                      ]  
[     O/P   i                      ]
[-----[/]---i                      ]
[                                  ]
[     PB     O/P              M1   ]
[-----[/]----[ ]-------------( )---]
[                                  ]
[     PB     M1      O/P      M2   ]
[-----[ ]----[ ]-----[ ]-----( )---]
[                                  ]
 
0
A.muthu Kumar,vacon
 
 
Question
why transformer rating in kva?
Rank Answer Posted By  
 Question Submitted By :: M.bhuvaneswari
I also faced this Question!!   © ALL Interview .com
Answer
transformer copper loss is directly propotional to 
current&iron loss is directly propotional to voltage. so 
transformer rating is in kva.
 
0
M.bhuvaneswari
 
 
Answer
we can't find the correct powerfactor , this is depn upon 
the loads thats why we are calling KVA..
 
0
Boopathi
 
 
Answer
In trafo we dont know what types of load connected at a 
time.i.e. inductive or rasistive but in motor load is same.
 
0
Ashiah
 
 
Question
What are the different methods for calculating Short 
Circuit Curren?
Rank Answer Posted By  
 Question Submitted By :: Kumar
I also faced this Question!!   © ALL Interview .com
Answer
SHORT CIRCUIT CURRENT IS DEPEND UPON TYPE OF FAULT OCCURE.
BY DESIGN EQUIVELENT CKT OF PERTICULAR FAULT. 
WE CAN GET SC CURRENT
 
0
Moti Rgpv
 
 
Question
How to calculate the average power factor in 3 phase 
unbalanced system
Rank Answer Posted By  
 Question Submitted By :: Deepakindi1
This Interview Question Asked @   Bhel
I also faced this Question!!   © ALL Interview .com
Answer
Simply calculate total KWH and KVH of last 24 Hrs and 
Divide into-Total KWH/Total KVH=Avg PF of last 24Hrs
 
0
Thakur
 
 
Answer
thanks, but  cosider that R ph pf is 0.8,y-ph pf is 0.6,and 
b ph pf is 0.7 what vlb the overall pf of three phase 
unbalanced 3phase system .
 
2
Deepak
[HUBLI ELECTRICITY SUPPLY COMPANY]
 
 
Question
Hi i am going to attend the interview for BHEL. can you 
please help out in knowing about the area of preparation. I 
am apprearing for Executive trainee post. Please share your 
views on this. Thanks 
Rank Answer Posted By  
 Question Submitted By :: Dalip Kumar
I also faced this Question!!   © ALL Interview .com
Answer
When and where is your interview?
 
0
John
 
 
Question
what is the meaning of the parameters labeled on the surge 
arrestor like 150/20 ???
Rank Answer Posted By  
 Question Submitted By :: Guest
I also faced this Question!!   © ALL Interview .com
Answer
I Am Not getting u r Question Actually The Surge Arrestor 
For Medium & High Voltage Substation is as
Voltage Rating Of LA ( KV )= 0.8* LINE Volgage of the 
Substation.

here 0.8 is earthing coefficent factor for solidely 
grounded system.....
 
0
Ashish
 
 
Answer
150/20 is the rating of voltages indicated on the surge 
arrester.
It means that the surge arresters step down the high 
voltage of 150  to 20.
 
0
Minal
 
 
Question
what is the diffrantial relay???????why we use it on the MDB
Rank Answer Posted By  
 Question Submitted By :: Guest
I also faced this Question!!   © ALL Interview .com
Answer
Differential relay is a current sensing zone protection 
relay.It is used to protect alternators,transformers from 
internal short ckt,internal earth faults.
 
0
Afrooz
 
 
 
Back to Questions Page
 
 
 
 
 
   