ALLInterview.com :: Home Page            
 Advertise your Business Here     
Browse  |   Placement Papers  |   Company  |   Code Snippets  |   Certifications  |   Visa Questions
Post Question  |   Post Answer  |   My Panel  |   Search  |   Articles  |   Topics  |   ERRORS new
   Refer this Site  Refer This Site to Your Friends  Site Map  Bookmark this Site  Set it as your HomePage  Contact Us     Login  |  Sign Up                      
Google
   
 
Categories >> Engineering >> Electrical Engineering
 
 


 

 
 Civil Engineering interview questions  Civil Engineering Interview Questions (3076)
 Mechanical Engineering interview questions  Mechanical Engineering Interview Questions (3289)
 Electrical Engineering interview questions  Electrical Engineering Interview Questions (13329)
 Electronics Communications interview questions  Electronics Communications Interview Questions (2363)
 Chemical Engineering interview questions  Chemical Engineering Interview Questions (416)
 Aeronautical Engineering interview questions  Aeronautical Engineering Interview Questions (77)
 Bio Engineering interview questions  Bio Engineering Interview Questions (17)
 Metallurgy interview questions  Metallurgy Interview Questions (79)
 Industrial Engineering interview questions  Industrial Engineering Interview Questions (163)
 Instrumentation interview questions  Instrumentation Interview Questions (2378)
 Automobile Engineering interview questions  Automobile Engineering Interview Questions (106)
 Mechatronics Engineering interview questions  Mechatronics Engineering Interview Questions (38)
 Marine Engineering interview questions  Marine Engineering Interview Questions (43)
 Power Plant Engineering interview questions  Power Plant Engineering Interview Questions (77)
 Engineering AllOther interview questions  Engineering AllOther Interview Questions (1196)
Question
importance of air gap in transformer
 Question Submitted By :: Electrical-Engineering
I also faced this Question!!     Answer Posted By  
 
Answer
# 1
We know that,The air gap controls the amount of magnetic
field produced for a given current. In the equation
∫HdL = n i , H is quite small in the iron because of its
high permeability. Nearly all of the integral accumulates in
the air gap even though the gap is very small compared to
the part of the closed path length in the iron. It reduces
the tendency of the iron to saturate to avoid harmonics in
the current.

thanking u
http://a2zengineering.blogspot.com/
z_hosen@yahoo.com
 
Is This Answer Correct ?    7 Yes 1 No
Md. Zakir Hosen
 
Answer
# 2
Actually the airgap in transformer is for transfer the
primary power to the secondary. Means the primary winding
input voltage level will be step up/down(Depends on type of
trf.) to the secondary winding.

This is exactly same with wats happening in a 3 phase ind.
motor between stator & Rotor.

Thats why we are calling ind. motor as "Rotating Trf".

Thanks ....
 
Is This Answer Correct ?    8 Yes 2 No
Arockia Doss.a
 
 
 
Answer
# 3
None of the above answers gives a satisfactory explanation.....some1 plz elaborate it....Thanks. 
Is This Answer Correct ?    1 Yes 0 No
Engr. Kashif
 
Answer
# 4
It limits the short circuit current of the transformer and it also control the Saturation of the core. 
Is This Answer Correct ?    0 Yes 0 No
Rakesh Patel
 
Answer
# 5
hi
air gap depend upon the applied voltage / range of voltage
in that gap.if it is not sufficient gap then breakdown of
the voltage will occur.
 
Is This Answer Correct ?    1 Yes 5 No
Nain
 

 
 
 
Other Electrical Engineering Interview Questions
 
  Question Asked @ Answers
 
What is the purpose of starter and choke in tube light? TATA 8
What is the difference between grounding & earthing?   8
what are the basic concept to design a out door Substation?   1
which type of motor is suitable for water pump? IIM 1
ONE B.O.T UNIT ??   1
what is the function of anti-pumping in circuit breaker? NCC 17
Why a dc generator gives result during two different condition,- 1)separately exited gen.- Eg=110 V, field current=0.25 A. 2) self exited gen.- Eg=30 V, field current=0.025 A.   1
can any tell me how to do wiring connection in L&T 3ph 4wire E301 CT operated energy meter, what is P1,P2,P3,P0. M1,M2,M3, L1,L2,L3.   2
how to calculate overall efficiency of diesel generator set? give us a formula with an example.   2
how capacitance is neglected in short transmission lines ? Qucab 1
funtion of choke L&T 4
ABOUT AC GENARETORS AND MAINTANANCE AND TYPES OF GENARETORS   1
 
For more Electrical Engineering Interview Questions Click Here 
 
 
 
 
 


   
Copyright Policy  |  Terms of Service  |  Articles  |  Site Map  |  RSS Site Map  |  Contact Us
   
Copyright 2013  ALLInterview.com.  All Rights Reserved.

ALLInterview.com   ::  KalAajKal.com