ALLInterview.com :: Home Page            
 Advertise your Business Here     
Browse  |   Placement Papers  |   Company  |   Code Snippets  |   Certifications  |   Visa Questions
Post Question  |   Post Answer  |   My Panel  |   Search  |   Articles  |   Topics  |   ERRORS new
   Refer this Site  Refer This Site to Your Friends  Site Map  Bookmark this Site  Set it as your HomePage  Contact Us     Login  |  Sign Up                      
Google
   
 
Categories >> Engineering >> Electrical Engineering
 
 


 

 
 Civil Engineering interview questions  Civil Engineering Interview Questions (3070)
 Mechanical Engineering interview questions  Mechanical Engineering Interview Questions (3286)
 Electrical Engineering interview questions  Electrical Engineering Interview Questions (13319)
 Electronics Communications interview questions  Electronics Communications Interview Questions (2362)
 Chemical Engineering interview questions  Chemical Engineering Interview Questions (414)
 Aeronautical Engineering interview questions  Aeronautical Engineering Interview Questions (77)
 Bio Engineering interview questions  Bio Engineering Interview Questions (17)
 Metallurgy interview questions  Metallurgy Interview Questions (79)
 Industrial Engineering interview questions  Industrial Engineering Interview Questions (163)
 Instrumentation interview questions  Instrumentation Interview Questions (2374)
 Automobile Engineering interview questions  Automobile Engineering Interview Questions (106)
 Mechatronics Engineering interview questions  Mechatronics Engineering Interview Questions (38)
 Marine Engineering interview questions  Marine Engineering Interview Questions (43)
 Power Plant Engineering interview questions  Power Plant Engineering Interview Questions (75)
 Engineering AllOther interview questions  Engineering AllOther Interview Questions (1195)
Question
If AVR fails in DG set what will be the affect?
 Question Submitted By :: Electrical-Engineering
I also faced this Question!!     Answer Posted By  
 
Answer
# 1
Failure of AVR means failure of Excitation, hence DG will
continue running but no EMF (Voltage) will be generated.
 
Is This Answer Correct ?    63 Yes 12 No
Sachin
 
Answer
# 2
I think
AVR = Automatic Voltage Regulator
Regulator Means it will controls the unit.So If AVR fails
in DG set we con't get constent continiues o/p voltage. Any
comments ?
 
Is This Answer Correct ?    33 Yes 2 No
Saleem.d
 
 
 
Answer
# 3
Failure of AVR means AVR will not deliver the excitation
voltaage to the exciter winding.Hance Excitor winding will
not be able to generate any excitor voltage.So there will
be no any field votage to rotor field winding and due to
this even if DG continious running but there will be no out
put voltage
 
Is This Answer Correct ?    31 Yes 4 No
Rajesh Patel
 
Answer
# 4
If AVR fails in DG sets,it means no d.C. supply recevied
by DG sets Coils, no magnetic field made & coil does`t
excited, result no output given by sets.
 
Is This Answer Correct ?    28 Yes 4 No
Dharamvir Punia
 
Answer
# 5
IF AVR fails in dg set then the exitation voltage is zero
and we do not get any output voltage.
 
Is This Answer Correct ?    15 Yes 0 No
Sandeep Jhajhra
 
Answer
# 6
then no emf will induce, because rotor is not energized.and
rotor will not become magnet at all.
 
Is This Answer Correct ?    9 Yes 2 No
Sunil Datta
 
Answer
# 7
AVR-AUTOMATIC VOLTAGE REGULATOR. AS THE NAME IMPLIES IT IS
USED FOR THE REGULATION OF VOLTAGE & VOLTAGE BUILD UP
PURPOSES.IT CONSISTS OF (VOLTAGE SENSING UNIT,VOLTAGE BUILD
UP CKT,PULSE WIDTH MODULATION CKT,etc...,).OBVIOUSLY IF AVR
FAILS THERE WILL BE NO VOLTAGE.SO DG RUNS WITHOUT VOLTAGE
AND THERE WILL BE NO LOAD.
 
Is This Answer Correct ?    9 Yes 2 No
Trilok Kumar
 
Answer
# 8
1. If the avr is not giving any output voltage ie DC to the
excitor then no voltage build up will be there.
2. If the avr is not changing the dc voltage as per load
demand then voltage variation will be observed.Which means
the automatic rerulation function of avr wrt load is not
working.Hence avr needs replacement.
 
Is This Answer Correct ?    5 Yes 0 No
Ajay
 
Answer
# 9
if avr fails,field excitation will be zero and hence no
rated voltage,but residual voltage will be always there.
dg breaker will trip due to under voltage protection .
 
Is This Answer Correct ?    5 Yes 2 No
Jai Prakash Narain Singh
 
Answer
# 10
it depends upon which type of avr is that .. if its an
static one than it will get tripped and no dc output and dg
set will not generate any voltage. but if avr having no
interlock with excitor than if avr fails than it will only
affect the regulation of voltage as excitation voltage is
already generating and being given to alternator so output
will be there but non-regulated
 
Is This Answer Correct ?    5 Yes 4 No
Chauhanalpesh
 

 
 
 
Other Electrical Engineering Interview Questions
 
  Question Asked @ Answers
 
what is resistance AITM 6
which motors is used in mixies   3
what is mean by power factor   9
is it possible to convert electrical energy to light energy for transmission purposes?   7
what is the right cable size for 100 hp mpter.   3
battery spicgravity mesuserd?   1
how to calculate the output power of vfd , please help me.   1
what is the use of neutral? IOCL 13
why we are using panel space heaters in different control schemes???? Mecon 3
thermal power station operation in general NTPC 11
where is used dc volage transformer,and what is highest capacity of transformer   2
WHERE WE CAN USE 3.5C CABLES INSTEAD OF 4C CABLES.why?   3
 
For more Electrical Engineering Interview Questions Click Here 
 
 
 
 
 


   
Copyright Policy  |  Terms of Service  |  Articles  |  Site Map  |  RSS Site Map  |  Contact Us
   
Copyright 2013  ALLInterview.com.  All Rights Reserved.

ALLInterview.com   ::  KalAajKal.com