ALLInterview.com :: Home Page            
 Advertise your Business Here     
Browse  |   Placement Papers  |   Company  |   Code Snippets  |   Certifications  |   Visa Questions
Post Question  |   Post Answer  |   My Panel  |   Search  |   Articles  |   Topics  |   ERRORS new
   Refer this Site  Refer This Site to Your Friends  Site Map  Bookmark this Site  Set it as your HomePage  Contact Us     Login  |  Sign Up                      
Google
   
 
Categories >> Engineering >> Electrical Engineering
 
 


 

 
 Civil Engineering interview questions  Civil Engineering Interview Questions (3112)
 Mechanical Engineering interview questions  Mechanical Engineering Interview Questions (3298)
 Electrical Engineering interview questions  Electrical Engineering Interview Questions (13411)
 Electronics Communications interview questions  Electronics Communications Interview Questions (2382)
 Chemical Engineering interview questions  Chemical Engineering Interview Questions (420)
 Aeronautical Engineering interview questions  Aeronautical Engineering Interview Questions (77)
 Bio Engineering interview questions  Bio Engineering Interview Questions (17)
 Metallurgy interview questions  Metallurgy Interview Questions (80)
 Industrial Engineering interview questions  Industrial Engineering Interview Questions (165)
 Instrumentation interview questions  Instrumentation Interview Questions (2393)
 Automobile Engineering interview questions  Automobile Engineering Interview Questions (106)
 Mechatronics Engineering interview questions  Mechatronics Engineering Interview Questions (38)
 Marine Engineering interview questions  Marine Engineering Interview Questions (45)
 Power Plant Engineering interview questions  Power Plant Engineering Interview Questions (78)
 Engineering AllOther interview questions  Engineering AllOther Interview Questions (1202)
Question
What is the difference between KV,KVAR,KVA,KW?
 Question Submitted By :: Electrical-Engineering
I also faced this Question!!     Answer Posted By  
 
Answer
# 1
kv- kilo volt= e.g 132kv ,220kv,400kv.
kw- active power=V.I cos@,kva -apperent power=v.I,kvar-
reactive power=V.I sin@,
kva2=(kw2+kvar2)
power factor=kw/kva
 
Is This Answer Correct ?    141 Yes 19 No
Ashish Patil
 
Answer
# 2
First take out odd kV= its the Potential difernce (Volt) in Kilo volts
KVA (Apparent power)=vector sum ( kW{active power}+kVAR{Reactive power))

now to tell u in breif in analogous way abot this KVA ,KVAR,KW

suppose we have to take one ball from A to B then

if the path is flat Road the power used is called active power

now if the path is upside of incline road the to take the ball we do extra effort
1) active power work to take ball from A to B
2) reactive power work to take in incline up side (extra work )

but total power used in this case will be greater and work done is same taking ball from A to B, this power is called as apparent power
active and reactive power
 
Is This Answer Correct ?    11 Yes 11 No
Tarun Aggarwal Ymca
 
 
 
Answer
# 3
kvar is reactive power while kva is active power
kvar= v*i sin(theta)
kva= v*i cos(theta)
total power= kva + kvar
 
Is This Answer Correct ?    7 Yes 23 No
Amar Nath Sharma
 
Answer
# 4
KVA-A=KV
KVAR-AR=KV
KW, I DONT KNOW SORRY.
 
Is This Answer Correct ?    10 Yes 37 No
Chungli Mangli
 

 
 
 
Other Electrical Engineering Interview Questions
 
  Question Asked @ Answers
 
how MW increase when steam input increase in turbine.   1
what type of euse we should use ? 1- High resistance & low temperature 2- High temperature low resistance   2
while conducting an experiment why we connect the armature rheostat in maximum position and field rheostat in minimum position   1
what is the Auto Mains Failure Panel function in DG?state its function?   3
can we replace d.c.motor by 3 phase induction motor for a particular application   4
How to select the different contactors ( starter combination) for different AC motors? what about fuse cappacity 4 different motors too? Equate 2
why vector group is ued   2
This is about the recent problem that we have faced in our project site. We have 6/7.5 MVA. 66/11kV three phase star - star power transformer. The neutral was solidly connected to the earthing mat. But because of high resistance of earthing mat (130 ohm on LV and 180 ohm on HV), one day LV side neutral earthing conductor melted and we had a huge damage. Can any one plz tell me what might happen when we connect power transformer neutral to the earthing mat which has high resistance (>100 ohm ) ?????   2
what is the problem of generator over voltage.?except automatic voltage regulator card   1
how can we avoid magnetostriction in transformer?describe the suitable methods. Bhel 2
how can we check a fully charged battery? KSEB 2
why dc supply is given for excitation of ac alternator?how dc can produce flux?   4
 
For more Electrical Engineering Interview Questions Click Here 
 
 
 
 
 


   
Copyright Policy  |  Terms of Service  |  Articles  |  Site Map  |  RSS Site Map  |  Contact Us
   
Copyright 2013  ALLInterview.com.  All Rights Reserved.

ALLInterview.com   ::  KalAajKal.com