Categories >> Engineering >> Electrical Engineering
 
 


 

 
 Civil Engineering interview questions  Civil Engineering Interview Questions (3111)
 Mechanical Engineering interview questions  Mechanical Engineering Interview Questions (3298)
 Electrical Engineering interview questions  Electrical Engineering Interview Questions (13407)
 Electronics Communications interview questions  Electronics Communications Interview Questions (2381)
 Chemical Engineering interview questions  Chemical Engineering Interview Questions (421)
 Aeronautical Engineering interview questions  Aeronautical Engineering Interview Questions (77)
 Bio Engineering interview questions  Bio Engineering Interview Questions (17)
 Metallurgy interview questions  Metallurgy Interview Questions (80)
 Industrial Engineering interview questions  Industrial Engineering Interview Questions (165)
 Instrumentation interview questions  Instrumentation Interview Questions (2389)
 Automobile Engineering interview questions  Automobile Engineering Interview Questions (106)
 Mechatronics Engineering interview questions  Mechatronics Engineering Interview Questions (38)
 Marine Engineering interview questions  Marine Engineering Interview Questions (45)
 Power Plant Engineering interview questions  Power Plant Engineering Interview Questions (78)
 Engineering AllOther interview questions  Engineering AllOther Interview Questions (1201)
Question
What is difference between 220v/50Hz & 120V/60Hz?
 Question Submitted By :: Electrical-Engineering
I also faced this Question!!     Answer Posted By  
 
Answer
# 1
220V/50HZ - indian standard of supply
120v/60HZ - american standard of supply
 
Is This Answer Correct ?    56 Yes 15 No
Raviteja
 
Answer
# 2
220V/50Hz system is used in india and Pakistan while
120V/60Hz is used in KSA and USA.

The advantage of 120V over 220V is human safety factor i.e.
less insulation required and less danger of electric shock
but it has the disadvantage that the initial cost increases.

Also size of electric equipment reduces with increase in
frequency such transformers etc.
 
Is This Answer Correct ?    38 Yes 6 No
Umar
 
 
 
Answer
# 3
both are /incorrect standard there is british and american
stanadard india is following british std.
 
Is This Answer Correct ?    32 Yes 10 No
Rk
 
Answer
# 4
WHEN WE USED 220 50 HZ SUPPLY WE CAN USE THIN ELECTRICAL
WIRES BUT FOR 120V 60 HZ SUPPLY WE NEED THICK WIRES.RICH
COUNTRU CAN PAY FOR 120V 60HZ AND SHOCK RATE IN CASE OF
120V IS LESS THAN 220V .HENCE FOR PERSONAL SAFETY REASONS
AND RICH , US. ETC ARE USING 220C 50HZ SUPPLY.
 
Is This Answer Correct ?    25 Yes 8 No
Mohit
 
Answer
# 5
220v/50 Hz is economic as thin conductor is required
usually pakistan and india use this as it is a British standard however it is more dangerous than 120v/60 Hz which is american standard and expensive as thick conductor is required
by ali raza electrical engineer(power)lahore pakistan
 
Is This Answer Correct ?    11 Yes 0 No
Ali Raza
 
Answer
# 6
Basicaly Pakistan, Uk, Europ are using 50hz and have
advantage less losses in reactive and easy transmission on
high voltage and disadvantade is large size of machine and
USA,KSA have 60 hz have advantage of smal size of machine
mean low coast and disadvantage is more losses in reactve
lose and low level of transmition
but both system have some advantage and disadvantage and
both area are try to improve their disadvantage to suite
the system for future
 
Is This Answer Correct ?    6 Yes 2 No
Bilal Ahmad
 
Answer
# 7
Ok 220v 50hz supply is economical then why americans are going for 120 60hz. 
Is This Answer Correct ?    0 Yes 0 No
Saravana Kumar S
 
Answer
# 8
220V/50HZ - less frequency of sine wave propogation has
large distacve between alternation of current between Phase
& Neutral and gives 220V at Phase to Neutral on 50Hz
Frequency. simply lenthy propogation with higher voltage.
(Depends upon the LT Power transformer output)

120v/60HZ - High frequency of sine wave propogation has
less distacve between alternation of current between Phase
& Neutral and gives 120V at Phase to Neutral on 60Hz
Frequency.simply fast propogation with lower voltage.
(Depends upon the LT Power transformer output)
 
Is This Answer Correct ?    3 Yes 5 No
Prasad Joshianwikar
 

 
 
 
Other Electrical Engineering Interview Questions
 
  Question Asked @ Answers
 
what is the meaning of pi value?   1
how to understand the controling circuits example star- delta-starter controling daigram please let me know GMR 3
how much air gap in induction motor as per the Indian standards?   1
How to select busbar?   2
how the capacitance is caluclated if the load is varying to keep the power factor constant(above0.95)   1
can anyone tell me the website for star-delta control diagram?   1
what is corona effect   3
What are all the points to be checked for a newly re-winded motor before installation Cisco 1
How to improve the power factor from 0.8 to 0.98? Also tell me cost vs benefit analysis.   2
Why transformer use to generator neutral earthing purpose ?   1
how to take the 3 phase ups input and collect single phase output   1