ALLInterview.com :: Home Page            
 Advertise your Business Here     
Browse  |   Placement Papers  |   Company  |   Code Snippets  |   Certifications  |   Visa Questions
Post Question  |   Post Answer  |   My Panel  |   Search  |   Articles  |   Topics  |   ERRORS new
   Refer this Site  Refer This Site to Your Friends  Site Map  Bookmark this Site  Set it as your HomePage  Contact Us     Login  |  Sign Up                      
Google
   
 
Categories >> Engineering >> Mechanical Engineering
 
 


 

 
 Civil Engineering interview questions  Civil Engineering Interview Questions (3112)
 Mechanical Engineering interview questions  Mechanical Engineering Interview Questions (3298)
 Electrical Engineering interview questions  Electrical Engineering Interview Questions (13406)
 Electronics Communications interview questions  Electronics Communications Interview Questions (2381)
 Chemical Engineering interview questions  Chemical Engineering Interview Questions (420)
 Aeronautical Engineering interview questions  Aeronautical Engineering Interview Questions (77)
 Bio Engineering interview questions  Bio Engineering Interview Questions (17)
 Metallurgy interview questions  Metallurgy Interview Questions (80)
 Industrial Engineering interview questions  Industrial Engineering Interview Questions (165)
 Instrumentation interview questions  Instrumentation Interview Questions (2390)
 Automobile Engineering interview questions  Automobile Engineering Interview Questions (106)
 Mechatronics Engineering interview questions  Mechatronics Engineering Interview Questions (38)
 Marine Engineering interview questions  Marine Engineering Interview Questions (45)
 Power Plant Engineering interview questions  Power Plant Engineering Interview Questions (78)
 Engineering AllOther interview questions  Engineering AllOther Interview Questions (1201)
Question
how to caluculate APFC panel rating, my running Load is 
1320KW, Present P.F 0.76 to 0.8 we need 0.98 p.f
 Question Submitted By :: Mechanical-Engineering
I also faced this Question!!     Answer Posted By  
 
Answer
# 1
KVAr = KW(multiplication factor )
1320(tan@1-tan@2)
cos@1-intial P.f
cos@2-final P.f
kvar=1320(0.541)
Kvar=715
 
Is This Answer Correct ?    79 Yes 13 No
Ak
 
Answer
# 2
we required runnig load and maximum demand also

then only we will get perfect KVAR
 
Is This Answer Correct ?    36 Yes 7 No
Anjaneyulu
 
 
 
Answer
# 3
Answer 3 is correct one. 
Is This Answer Correct ?    22 Yes 10 No
Prakash Suhane
 
Answer
# 4
Please refere Capacitor manufacturers catlogue where there
is table to improve PF Vs. Load.
 
Is This Answer Correct ?    46 Yes 35 No
Ytd
 
Answer
# 5
please give the details how much is your inductive load (
motor ) or give the connected load list & presently
connected capacitor.( kvr)
 
Is This Answer Correct ?    8 Yes 0 No
Santosh
 
Answer
# 6
Input Initial Power Factor : .76
Input Desired Power Factor: .98
Input Load KW (KW) : 1320 KW


SO KVAR NEEDED TO ATTACHED :860 KVAR IF U WANTS .98

KVAR NEEDED TO ATTACHED :940 KVAR IF U WANTS .98
THESE 2 PANELS U NEED TO BE INSTAL ON THIS CONNECTED LOAD
AND ALSO DEMAND WILL GO DOWN

VISIT: www.sigmacontrols.net
 
Is This Answer Correct ?    15 Yes 9 No
Ajeet Singh
 
Answer
# 7
CHECKED THE WHOLE DAY LOAD CACLULATION
CHECHED THE KVARH, KVA, KWH READING
 
Is This Answer Correct ?    8 Yes 3 No
Tejas Doli
 
Answer
# 8
KVAR Required = Operating KW x [Tan (A1) - Tan (A2)]

Where A1 = Inverse Cosine of present power factor
= Cos-1(0.78)
= 38.739
A2 = inverse Cosine of desired power factor
= Cos-1(0.98)
= 11.478
Tan(A1)=Tan(38.739)=0.8022
Tan(A1)=Tan(11.478)=0.2030
Hence,
KVAR Required=1320 x (0.8022-0.2030)
SO KVAR NEEDED TO ATTACHED=790 kVAR
 
Is This Answer Correct ?    4 Yes 1 No
Deniram Anandrao Nikhare
 
Answer
# 9
KVAR Rating = 860kvar or 714kvar 
Is This Answer Correct ?    8 Yes 6 No
Md.aftab Alam
 
Answer
# 10
290 kvar panel of 14 stage
conected relay {fifo}
 
Is This Answer Correct ?    4 Yes 2 No
Ajay Sharma
 

 
 
 
Other Mechanical Engineering Interview Questions
 
  Question Asked @ Answers
 
Which Type of Stresses will be acted on Helical Springs? Bhel 4
WHY MECHANICAL ENGG ARE RECRUTED IN IT COMAPNIES? TATA 2
why diesel engine does not have spark plug like petrol engine, how ever petrol is better fuel than diesel? HMT 16
which type of shaft is preferred for power transmission, solid or hollow one?   5
can you email me addres of kartar coaching GKP for rrb mombai exams for techanical cadre i.e diploma in mechenical engg   1
Steam is a vapour or a gas ? BDL 5
What will be the cause of the loose compression in a cylinder?   3
How do i calculate compressor capacity in a refrigeration system?   5
The capacity of the compressor is considered to be maximum when the temperature of the air is a.Maximum b.minimum c.moderate d.   10
Tell you your selfe ? Call-Centre 12
What type of pump is commonly used is feed water system in boiler?   1
What does it mean- 10mm of mercury pressure (See B.L thereje book page 1331)   2
 