ALLInterview.com :: Home Page            
 Advertise your Business Here     
Browse  |   Placement Papers  |   Company  |   Code Snippets  |   Certifications  |   Visa Questions
Post Question  |   Post Answer  |   My Panel  |   Search  |   Articles  |   Topics  |   ERRORS new
   Refer this Site  Refer This Site to Your Friends  Site Map  Bookmark this Site  Set it as your HomePage  Contact Us     Login  |  Sign Up                      
Google
   
 
Categories >> Engineering >> Electrical Engineering
 
 


 

 
 Civil Engineering interview questions  Civil Engineering Interview Questions (3129)
 Mechanical Engineering interview questions  Mechanical Engineering Interview Questions (3300)
 Electrical Engineering interview questions  Electrical Engineering Interview Questions (13439)
 Electronics Communications interview questions  Electronics Communications Interview Questions (2385)
 Chemical Engineering interview questions  Chemical Engineering Interview Questions (420)
 Aeronautical Engineering interview questions  Aeronautical Engineering Interview Questions (77)
 Bio Engineering interview questions  Bio Engineering Interview Questions (17)
 Metallurgy interview questions  Metallurgy Interview Questions (80)
 Industrial Engineering interview questions  Industrial Engineering Interview Questions (165)
 Instrumentation interview questions  Instrumentation Interview Questions (2401)
 Automobile Engineering interview questions  Automobile Engineering Interview Questions (107)
 Mechatronics Engineering interview questions  Mechatronics Engineering Interview Questions (38)
 Marine Engineering interview questions  Marine Engineering Interview Questions (45)
 Power Plant Engineering interview questions  Power Plant Engineering Interview Questions (80)
 Engineering AllOther interview questions  Engineering AllOther Interview Questions (1203)
Question
why earth hole size is biggest in plug point?
 Question Submitted By :: Electrical-Engineering
I also faced this Question!!     Answer Posted By  
 
Answer
# 1
1) See, this is to have a least resistance path to the flow
of earth fault current. As earth point have larger area, it
is having low resistance.( R=6l/a ).

2)To have very firm connection to earthed point.
 
Is This Answer Correct ?    43 Yes 2 No
Yogesh Lokhande
 
Answer
# 2
The resistance of the Conductor is depending upon the area
of cross section of conductor i.e(R=6L/A), so we are
connected earth wire to the big one terminal of the socket
point as well as 3 pin top. To flow the fault current
through the terminal to earth easily.
 
Is This Answer Correct ?    20 Yes 2 No
Mahadeva
 
 
 
Answer
# 3
It is biggest in length and dia... main reasons are..

1.To connect the earthing first.. instead of phase... so if
there is any internal short in the equipment... it willl
not harm to the operator.

2. To provide least resistance path.
3. As the short circuit currents are high... it must have
high cross sectional area...
 
Is This Answer Correct ?    18 Yes 0 No
Ramesh Kumar K
 
Answer
# 4
There is no connection with cross sectional area and least
resistance path for short circuit current.

The size of earth pin is longer and bigger because of only
two following reason (you may refer BS1363)

The longer earth pin ensures that the earth path is
connected before the live pins, and remains connected after
the live pins are removed.

The design of the earth pin being of a larger
dimension prevents it from being inserted into the phase or
neutral sockets should this be attempted in error.

so don't get confussed
 
Is This Answer Correct ?    14 Yes 2 No
Vikas Jauhari
 
Answer
# 5
1) To withstand fault current. that is any short circuit
occur, all fault currents flow through earth.so earth
pin and plug give heavily.
2) any where should give earth first then connect power. so
earth pin give long.
 
Is This Answer Correct ?    14 Yes 4 No
Mayilsamy
 
Answer
# 6
Earth point is long and big because

1,we know if the cross section area increase resistance decreases.To decreases the resistance ,dia increased.And the length is to conduct first before power supply inserts
so when short circuit occurred the short circuit current will conduct earth point first,and flows through it because resistance is low
 
Is This Answer Correct ?    5 Yes 0 No
Prathap
 
Answer
# 7
The resisitance of conuctor is directly propotional to
length of conductor and inversly propositional to condutor
area, so plug point earth point hole soze is large than
compare to phase and neutral
 
Is This Answer Correct ?    4 Yes 0 No
Gunasekaran
 
Answer
# 8
The size of earth pin is longer and bigger because of only
two reason as per British standard 1363

The longer earth pin ensures that the earth path is
connected before the live pins, and remains connected after
the live pins are removed.

The design of the earth pin being of a larger
dimension prevents it from being inserted into the phase or
neutral sockets should this be attempted in error.

ok
 
Is This Answer Correct ?    2 Yes 0 No
Nikunj Patel
 
Answer
# 9
Hi All

As we know that Resistance is directly proportional to
lenth and Inversily proportional to area of conductor .
due to more area of cross section of earth point in compare
to Phase and neutral short circuit current will flow to
direction which have low resistance i.e. to earth point.
 
Is This Answer Correct ?    1 Yes 0 No
Umesh Yadav
 
Answer
# 10
It is big and lightly long because of

1. To connect the earthing first.
2. to grip it solid
 
Is This Answer Correct ?    10 Yes 11 No
R_phand2006
 

 
 
 
Other Electrical Engineering Interview Questions
 
  Question Asked @ Answers
 
why humming sound occured in h HT transmission line   3
What will happen if the 50HZ Transformer is connected with 60HZ power Supply   1
what is earthing   1
Can the field winding in synchronous machines be placed on stator?What is the limitation of such arrangement?   2
define regulation   3
1. If we apply dc supply to the primary winding of transformer it will be burnt out. similarly dc supply is given to field winding of syn. motor and armature winding of dc motor, they are safe. (Remember both windings inductive nature) what is the reason behind that?   1
what are the current specifications of bus ducts ? i ve seen in IPBD bth 22000 A and 1500 A in 400 kv switchyard . why it is so??   1
what is load shedding KSEB 4
what is differents between static stablizer and servo stablizer   3
assume we are put both df/dt and vector surge relay in same bus the df/dt relay setting is +5 hz an -5HZ. we want operat the vector surge relay before the df/dt how i calculate the setting of the vector surge relay.   1
Two alternators say 1 & 2 are poised to parallel operation. But at the time of paralleing alternator 2 gets out of the system by tripping Earth fault relay. Please send me reply why this is happening?   2
what is the importance of neutral in elctrical system? Iocl 2
 