ALLInterview.com :: Home Page            
 Advertise your Business Here     
Browse  |   Placement Papers  |   Company  |   Code Snippets  |   Certifications  |   Visa Questions
Post Question  |   Post Answer  |   My Panel  |   Search  |   Articles  |   Topics  |   ERRORS new
   Refer this Site  Refer This Site to Your Friends  Site Map  Bookmark this Site  Set it as your HomePage  Contact Us     Login  |  Sign Up                      
Google
   
 
Categories >> Engineering >> Electrical Engineering
 
 


 

 
 Civil Engineering interview questions  Civil Engineering Interview Questions (3070)
 Mechanical Engineering interview questions  Mechanical Engineering Interview Questions (3286)
 Electrical Engineering interview questions  Electrical Engineering Interview Questions (13320)
 Electronics Communications interview questions  Electronics Communications Interview Questions (2362)
 Chemical Engineering interview questions  Chemical Engineering Interview Questions (414)
 Aeronautical Engineering interview questions  Aeronautical Engineering Interview Questions (77)
 Bio Engineering interview questions  Bio Engineering Interview Questions (17)
 Metallurgy interview questions  Metallurgy Interview Questions (79)
 Industrial Engineering interview questions  Industrial Engineering Interview Questions (163)
 Instrumentation interview questions  Instrumentation Interview Questions (2374)
 Automobile Engineering interview questions  Automobile Engineering Interview Questions (106)
 Mechatronics Engineering interview questions  Mechatronics Engineering Interview Questions (38)
 Marine Engineering interview questions  Marine Engineering Interview Questions (43)
 Power Plant Engineering interview questions  Power Plant Engineering Interview Questions (75)
 Engineering AllOther interview questions  Engineering AllOther Interview Questions (1195)
Question
What will be the size of cable required for 5.5 KW motor ( 
Full load current 10 Amps approx.), Starting current with 
DOL is 120 Amps. Aprrox. Short circuit current with LLLG 
fault is 2000 Amps Approx.
 Question Submitted By :: Electrical-Engineering
I also faced this Question!!     Answer Posted By  
 
Answer
# 1
4 sq. mm is sufficient. In our plant we are using 2.5 sq. mm for 5.5 KW and 4 sq. mm for 11 KW. 
Is This Answer Correct ?    6 Yes 2 No
Birinchi87
 
Answer
# 2
6 sq mm copper cable and 10 sq mm if the usage is
non-stop.cables can withstand heavy currents for short periods.
 
Is This Answer Correct ?    3 Yes 1 No
K.prakashchandra
 
 
 

 
 
 
Other Electrical Engineering Interview Questions
 
  Question Asked @ Answers
 
how to amps calculate from 1KVA?   11
why we used servo motor insted of inducation motor?   1
what is the phase voltage and line voltage in 2 phase power supply? EID-Parry 1
why our indian system choose the 230 volt for single phase&415 for 3-phase voltage,in forign side 110 volt is used what is the difference Jindal 4
Why two main buses and one transfer bus scheme not using for 400kV switchyard   4
if field current decreases how can the speed increase in the unloaded dc series motor   1
what is the principal of braker   4
what is the function of commutator in dc motor?   3
What is Diff. btw Cat-5 & Cat-6 Network Cables??? Emerson 3
what is ring main unit(Rmu)? what is its function   1
A 2D array X(7,9) is stored linearly column wise in a computers memory.Each element requires 4 bytes for the storage of the value.If the first byte address of X(1,1) is 3000,what could be the last byte adress of X(5,8)? TCS 2
where is the primary of CT??   2
 