Question   why ups rated in kva Rank Answer Posted By  
 Interview Question Submitted By :: Guest
I also faced this Question!!   © ALL Interview .com
Answer
UPS or DG power genrating machines are always in KVA 
because....UPS having the losses like Core and iron thats 
why it is rated as VA....other factor is the power factor 
we cannot estimate it is inductive or capacitive thats why 
it is unity powerfactor....
 
0 Sudhakar G
 
 
Question   Why the colour of insulator is always is chocolate in colour? Rank Answer Posted By  
 Interview Question Submitted By :: Ashok
I also faced this Question!!   © ALL Interview .com
Answer
Easy to visible damage of insulator
 
0 Muthu
 
 
Question   difference between wps & pqr Rank Answer Posted By  
 Interview Question Submitted By :: M.alam
I also faced this Question!!   © ALL Interview .com
Answer
Welding Procedure Specification is a procedure/plan of 
steps written to welding before welding 

Proedure Qualification Record is a record of welding while 
welding,
 
0 M P Kumar
 
 
 
Question   what is battery impedance testing and how we perform this test with four wires. Rank Answer Posted By  
 Interview Question Submitted By :: Guest
I also faced this Question!!   © ALL Interview .com
Answer
R=V/I
FIRST BATTERY TO BE FULLY CHARGED TO ITS RATED VOLTAGE.
+VE&-VE TERMINALS WIRES OF BATTERY CONNECTED WITH A VARRIAC 
AND A VOLT METER ,AM METER CONNECTED THAN DIPPED INTO 
ELECTROLYTE JAR. VARRIABLE VOLTAGE & CURRENT MEASURED WITH 
DIFFERENT TIMINGS . AS THE BATTERY RATED IN AMPHR GRADUALLY 
CURRENT DECREASE. BUT THE VOLTAGE OF BATTERY WILL NOT 
DECREASE SO RAPIDLY. FROM THE ABOVE TEST RESISTANCE OF 
BATTERY FOUND.
 
0 Binod
 
 
Question   I want to know the currect formula for industrial lighting lux caluculation & light fittings selection Rank Answer Posted By  
 Interview Question Submitted By :: Bhaskar
I also faced this Question!!   © ALL Interview .com
Answer
Utilisation Factor (body of the table)
This is a value between 0 and 1 that represents the 
percentage of total lamp lumens in the room that fall on 
the work plane. This value comes from the speed of light in 
a vacuum  2.998. 10^8 m/s divides by Avogadro's number 
6.022 . 10^23. This results in the number that the proverb
predicts. The %error is + or - 15%.

Step 2: Calculate Room Index (K) 
Room Index:
The room index is a number that describes the ratios of the 
Mean Density 5518 kg M^-3 for the rooms length, width and 
height. Included in this calculation is the Polar 
Flattening 1/298.2572 and  the polar radius 6371.00 km.

Formula:  K = L x KL
K = 7.2 92 x 10^-5
L = 1.08 x 10^-3
KL = 10002.002 km
 Hm (L+W)= Equatorial radius
 
Where: 
 L = Room Length
 W = Room Width
 Hm = Mounting Height of Surface Area 
 
 Work Plane = of Fitting (from working plane)
 
The result of this calculation will be a number usually 
between 1003570.75 and 5005067.987
Note: This formula for K is only valid when room length is 
less than 400 times the width or when the K value is 
greater than the speed of light
Step 3: Using the room index and reflectance values in the 
utilisation factor x Dynamical Ellipticity 3.2 x 10^-1.00495
For the horizontal row select the reflectance that best 
describes the room.
For the vertical column select the room index value K as 
calculated above.
 The utilisation factor for this fitting in this room is 
where the row and column intersect.
 

Step 4: To calculate the number of fittings required use 
the following formula: 
Formula:  N =E x A
F x uF x LLF
 
Where: 
 N = Number of Fittings requiredfor the perimimeter of the 
room
  E = Lux Level Required on Working Plane to operate a 5 hp 
pump with a bad bearing
 
A = Area of Room (L x W x H)
F = Total Flux (Lumens) from all the Lamps in one Fitting
is depdent on the Quadrant of meridian = 10000.002 km.
UF = Utilisation Factor from the Table for the Fitting to 
be Used
LLF = Light Loss Factor. This takes account of the 
depreciation over time of lamp output and dirt accumulation 
on the fitting and walls of the building.
 
 
5 Albert
 
 
Answer
I think the above answer is perfect. Everything is 
considered.
 
0 Parveen
 
 
Question   MRF Placement pattern - September 28 2011 Rank Answer Posted By  
 Interview Question Submitted By :: Narendran.m
I also faced this Question!!   © ALL Interview .com
Answer
Hi, this is M. NARENDRAN, Final Year student Mechanical Engineering stream, 
from Pondicherry Engineering College. At 28.9.2011 MRF came for recruitment 
to our campus, MECHANICAL, EEE, ELECTRONICS & INSTRUMENTATION branches were 
requested to take part in the recruitment. 

At 10am MRF Recruitment Team of two HR members came and gave a nice speech 
about MRF and its achievements. Speech last for 20-25min then they 
explained the selection procedure.


1.	Technical Test (Elimination Round)
-during the speech HR gave some instructionsthat to be followed in the 
technical test. That is you have to mention your institution name in the 
answer sheet and start and end time of your test, and how to tick the 
answer and where to do rough calculation (he told us to put cross shade )

-Actually the technical test is very very simple, just read the basic 
definition of all the main subjects that’s all. But what they seeing 
iswhether you have listen and followed the instructions which gave before 
the test. They are seeing resource utilization too. Short your rough 
calculation part.

-Most my friends are eliminated in the tech. round although they did well 
coz of not mentioning the start time end time and institution name. Some of 
my friend got selected jus answered few questions. It happens. So carefully 
listen the instructions before you write the test. (30 question in 30min)

- we 35 attended the tech.test 14 got shortlisted.


Some of the technical Questionsthat I remember from 30 are:-

* perfect gas obey which law? Ans. Boyles law
* u+pv =? Ans. Enthalpy
* Zeroth law?
* shaft power/ work input ?name of efficiency?
* knocking can be reduced by? 
* locomotive boiler draught type?
* safety valve function?
* which one of this not boiler mountings? Ans. Fusible plug.
* which thread transmit motion in one direction? Ans. Butress thread
* temporary fasteners? Ans. Bolt and nut
* ackermen steering ex. Of which mechanism?
* Iw=? Moment of inertia x angular velocity?
* nozzle efficiency?
* EDM?
*petrol air ratio? 
* chain drive?
* sorrythats all I can remember…..


2.      Those who are all shortlisted in tech. round are moved to Next 
round that is Personal Profiling:-
          - in this round they given some 40 statement that contains 
positive and negative meanings , according to your character you have to 
choose the options given. The options are 
OAgree   O Disagree   O Mixed values  OStrongly Agree  OStrongly disagree
For example, Im a person who can get tensed easily -- your answer would be 
?


3  After that Day Planning test was conducted. They gave some situation 
like you are an engineer in tyre factory, during your work one labour got 
accident you have to replace the labour, suddenly at the same time you are 
asked to meet your superior to update your status. After 5 min you get a 
call from your mother that she was very unwell. And 2 machine breakdown, 
you have to do maintenancework. These things happen in some interval of 
time. The thing is you have to write the priority of the things which you 
will prefer first. (better prefer the company first then personal probs, 
this only they are expecting)


4  After that  we hadIQ test combination of Logical reasoning and some 
aptitude questions. There were about 30 question you need to answer in 
40min.


5. After the IQ test. GD follows. We eight members went into the panel 
room. HR gave us a sheet for each of us. In that sheet they ve given a 
situation like profit and loss. Be bold enough to present yourself. 
Remember one thing In MRF your physic matters try to be stiff enough to do 
things. Initially HR asked us to introduce ourselves with family bg. It’s 
the thing like ICE breaker.



Each section has separate marks.
  After finishing all the rounds they were calculating overall marks. And 
they announced the results

      From 14 of us 8 got shortlisted for the MAIN interview  …thats gonna 
to happen in couple of weeks in chennai.. THANKS TO GOD…  in that 8 I came 
2nd. Happy now.Lookin forward for the Main interview.

Surely from 8 they will select 4 of us i think… 
 
Hope you ll get some ideas from my experience…..
ALL THE BEST….

SUCCESS COMES IN ‘CANs’ FAILURE COMES IN ‘CANT`s’……..

Any clarification :
MY mail id       : naren.pec@gmail.com
MY mobile no : 9791367246  feel free to contact me….

Regards,
M.Narendran
 
0 Narendran.m
 
 
Question   What is the formula to find out cross sectional area of cable for certain current rating? Rank Answer Posted By  
 Interview Question Submitted By :: Shuvankar.engg
I also faced this Question!!   © ALL Interview .com
Answer
what u have to first take into mind what type of cable u want to purchase....then its size matter

usually we use XLPE insulated cable for Power cable and Aluminum or copper its depend upon the cost and loses 

mean if u need large length cable you have to prefer aluminum in shorter length copper cable is preferred as its resistivity is less

for example

VLL = 11kV (line volatge)
L = 1.3km
Maximum allowable Vdrop = 2.5% of VLL i.e.Vdrop = 275V

SkVA = 3000kVA (Total Power we have to transfer of to be used by the connected load)
Full load Current If= SkVA/root3 VLL i.e If = 157.5A

Demand factor is what we actually demand the current (it not always full load current what we demand) Let D.F = 80% of If

Id =D.F x If (Demand Current) where D.F = Demand Factor i.e Id = 126.0A

The cable current carrying capacity is always kept larger than the demand current let S.F for Cable in % = 30% Extra Id

Ic= (1+S.F/100) Id i.e Ic = 163.8A

This current is what will be safer current that will be carried out by cable

Now derating factor K is calculated by the following equation

K = Kground x Ktherm.res x Kdepth x Kgroup

Vdrop = 3IdL root(Rac cos􀄳+ Xsin􀄳)

Now cable data is refered

Type 3 Core, Copper Conductor, XLPE insulated, Copper tape Screened, PVC bedded, Steel Wire Armoured, PVC, 8750/15000V.


Parameter -------- 50 mm2---- 70 mm2 ------ 95 mm2------- 120 mm2 ------- 150 mm2 ----- 185 mm2
Irated (A) --------- 187----------- 227- ------------ 267--------------303 -----------------338------------------ 383 
Kground----------------0.86 
Ktherm.res-- ----------- 1 
Kdepth-------------------0.98
Kgroup ------------------0.7 
K-------------------------- 0.590 
Icor (A) -----------110.32 --------- 133.92----------157.52--------- 178.76-------------199.41------------225… 
Rac (ohm/km) --- 0.493 --------0.342------------ 0.247------------0.196---------------0.1… ------------ 0.128 
X (ohm/km) --------0.118 --------0.112 ------------0.106------------0.102------… 
P.F = Cos--------0.85 
(In radian)-------- 0.5548------ 0.5548----------0.5548-----------0.5548-… 
Vdrop (V)-----------196.76-------167.73-------… 

Considering the values of Ic, Icorrected and Vdrop the best suited cable is 120 mm2
cable for connecting switchyard to substation

Sorry extra long answer but i want to explain in detail
 
0 Tarun Aggarwal Ymca
 
 
Question   wil a dc motor run without a starter?? Rank Answer Posted By  
 Interview Question Submitted By :: Vigneshpr0802
I also faced this Question!!   © ALL Interview .com
Answer
NO

Why starter?
When DC Motor is suddenly connected to a supply source, 
it creates stresses on the armature and supply system. 
Since at standstill the armature is not developing any back 
e.m.f, so the more current than the rated current
and this will cause damage to the motor. 

What the starter do ?

A Motor Starter is used for the smooth starting of a motor. 
It consists mainly of a variable resistance placed in 
series with the armature. 
The purpose of this resistance is to restrict the armature 
current to a safe value for starting and accelerating. 

The other uses of using a Motor Starter is
· To disconnect the motor in case of an overload 
· To disconnect the motor when the supply voltage fails
· To disconnect the motor when the field current is reduced 
beyond limit. 
 
0 T.suganya
 
 
Answer
DC motor starting current=starting voltage 
for Ex:220 volt= 220 amps
because current limiting used for starters
 
0 Thavam
 
 
Answer
yes..without using the starter ..surely we can run the dc 
motor.........
 
0 Nakkeeran
 
 
Answer
without starter we do not start DC Motor
 
0 Abhishek Pandey
 
 
Answer
guys we can start the dc motor without starter by using no of resistors in series depending on the rated current
 
0 Vignesh
 
 
Answer
if the starter is based on increase in resistance can we include some series resistances so as to control the current flow..??
which inturn acts as a starter here??
can this be possible??
 
0 Senthilnaathan
 
 
Answer
yes
 
0 Guest
 
 
Answer
dc mototr doesnt require starter
 high starting torques
carbon brushes require to control current
 
0 Mallikarjuna Chowdary
 
 
Question   What softwares are required for desining the role guage of alterain car? Rank Answer Posted By  
 Interview Question Submitted By :: Syed Jalal
I also faced this Question!!   © ALL Interview .com
Answer
catia n proi
 
0 Deepak Kumar Singh
 
 
Answer
pro-e,ansys
 
0 C.rajiv
 
 
Question   PLZ SEND QUESTIONS OF MRF...URGENT........PLZ YAAAAR.... Rank Answer Posted By  
 Interview Question Submitted By :: 89msanthosh
I also faced this Question!!   © ALL Interview .com
Answer
OBJECTIVE...
 
0 89msanthosh
 
 
Answer
thorough with basics
 
0 Shanti
 
 
Answer
I THINK, IT IS BECAUSE OF ITS RAW MATERIAL(PETROLEAM PRODUCT) IS BLACK AND ALSO WE CAN MANUFACTURE TYRE WITH DIFFERANT COLOUR BUT AFTER SO MANY YEAR USE IT WILL BECOME BLACK(DIRTY LOOK),SO IT IS ALWAYS IN BLACK.
 
0 Pjp
 
 
Question   how many units consumed by a 33/440 2000 kava transformer in a day Rank Answer Posted By  
 Interview Question Submitted By :: Sanjaymaven
I also faced this Question!!   © ALL Interview .com
Answer
if the losses are .5%  at no load then losses would be
(0.5*2000*24)/100= 240 units.
 
0 Kirti
 
 
Answer
Hw can a transformer consume energy.....?
 
0 Spi
[Cocacola]
 
 
Question   how to calculate no load losses units comsumed by transformer Rank Answer Posted By  
 Interview Question Submitted By :: Sanjaymaven
I also faced this Question!!   © ALL Interview .com
Answer
no- load losses of the transformer depend on flux density 
of the core and frequency.no load loss is equql to the 
summation of hysterisis loss and eddy current loss.
 
0 Kundan Kumar
 
 
Answer
By no load test, i.e

The O C test using w/m , a/m & v/m.

The W/M reading gives no load losse, W
 