Is this allowed?
01 WS-TABLE.
03 FILLER-X PIC X(5) VALUE 'AAAAA'.
03 WS-EX REDEFINES FILLER-X OCCURS 5 TIMES PIC X(1).
can redefines clause be used with occurs clause?
Can a REDEFINES clause be used along with an OCCURS clause?
if yes,
01 WS-TABLE.
03 WS-TABLE-EL OCCURS 5 TIMES PIC X(1) VALUE 'A'.
03 WS-EX REDEFINES WS-TABLE-EL PIC X(5). What can you
expect?
if no,why?
Hi all,
I have a following requirement to write the cobol program.
I have to load the 129 variables from input sequential file
which are in excel sheet to the cobol inernal table. and
after loading into table i have to compare this data with
the business file. here compare means controlling the data
whether the format(numeric,alpha) is same in the business
file and in the table??? i have the same data in input and
business file.
could anyone please give me any idea of the logic?//
i have all the 129 different variables(129rows,1 column)is
there .
How can I find the maximum value of a field in a file while
reading the file dynamically? without using sort function.
Suppose i have a file with fields Timestamp, description,
teamname, teamnumber.. i have read the file till end and
find the maximun value of timestamp which is not in sorted
order.. can we use function max(timestamp)?
What you have to do in the display file when you are using
message subfile?
16
When you compile a CICS program, the (pre)compiler puts an
extra chunk of code. Where does it get stored
302
how do you resolve -818 error in db2. where we have to see
time stamp token. i said by seeing in load module and
plan .is it correct or not. give clear explination for how
to see time stamp token
Q:Hi all,i want accurate answer with code using in built
functions.please sent me code as soon as posible.
I have program nmed PGM1 which '' RETRIEVE Current
production date''should correctly default the production
date for the user who is issuing raw materials to the
manufacturing.The production date can be different from the
celendra date.
However, the program does not make the correct adjustment
for all manufacturing plants.
there is a parameter which determines the
production start time e.g. 07:00 if the system time
precedes this,the program subtracts one from the celendra
day.This work fine when the celendar day starts after
production day as it does in England,the system should be
adding one to the celendar day during the overlap.
unfortunately the program was desined to assumed the
celendar day always starts before the production day.
Change required in the program:
Change the
PROGRAM PGM1 to use the new parrameter to decide whether to
add or subtract 1 from the celendar day when determining
the production date.
<CICSFault
xmlns="http://www.ibm.com/software/htp/cics/WSFault">DFHPI10
08 05/13/2009 05:47:14 FSCIBM SOAP message generation
failed because of incorrect input
(INPUT_STRUCTURE_TOO_SMALL ).</CICSFault>
Can anyone suggest how to handle this type of error?
6
WHICH REPLY CODE IS USED BT sftp ? ...
(e.g.226 is used by FTP IF FILE IS TRANSFERED)
24
how can we override data definitions in jcl.